Product Code : SL-4033SD
Product Description

FEATURES :

  • Frequency and time weighting meet IEC 61672 class 1
  • A & C weighting networks comply with standards.
  • 0.5" standard microphone head.
  • Time weighting (Fast & Slow) dynamic characteristic modes.
  • Build External calibration VR.
  • Auto range & Manual range selection.
  • Available for external calibration adjustment.
  • Condenser microphone for high accuracy & long-term stability.
  • Memory function to store the Max. & Min. value.
  • Hold and Peak Hold functions.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds.
  • Manual datalogger is available ( set the sampling time to 0 second ), during execute the manual datalogger function, it can set the different position ( location ) No. ( position 1 to position 99 ).
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information (year / month / date / hour / minute / second ) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity : 1 GB to 16 GB.
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
  • Heavy duty & compact housing case.

Specification :

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).

Measurement Range

30 - 130 dB.

Resolution

0.1 dB.

Function

dB ( A & C frequency weighting ), Time weighting ( Fast, Slow ), Peak hold, Data hold Record ( Max., Min. ).

Accuracy
(23 + 5oC)

Characteristics of " A " frequency weighting network meet IEC 61672 class1 Under 94 dB input signal, the accuracy are :

31.5 Hz

+2.0 dB

63 Hz

+1.5 dB

125 Hz

+1.5 dB

250 Hz

+1.4 dB

500 Hz

+1.4 dB

1 K Hz

+1.1 dB

2 K Hz

+1.6 dB

4 K Hz

+1.6 dB

8 K Hz

+ 2.1 dB , -3.1 dB

12.5 KHz

+ 3.0 dB, -6.0 dB

16 KHz

+ 3.5 dB, -17.0 dB

Remark :
The above spec. are tested under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only.

Frequency

Weighting

Network

Characteristics of A & C.
A weighting :
The characteristic is simulated as "Human Ear Listing" response. Typical, if making the environmental sound level measurement, always select to A weighting.
C weighting :
The characteristic is near the "FLAT" response. Typical, it is suitable for checking the noise of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment.

Data hold

To freeze the measurement value.

Peak hold

To keep the peak ( max. ) measurement value.

Time weighting (Fast & Slow)

Fast - t= 200 ms
Fast" range is simulated the human ear response time weighting.
Slow - t = 500 ms
Slow" range is easy to get the average values of vibration sound level.

Range selector

Auto range :
30 to 130 dB.
Manual range :
3 range, 30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step, with over & under range indicating.

Frequency

31.5 to 16 KHz.

Microphone type

Electric condenser microphone.

Microphone size

Out size, 12.7 mm DIA. ( 1/2 inch).

Calibration VR

Build in external calibration VR, easy to calibrate on 94 dB level by screw driver. Calibrated via external SOUNDCALIBRATOR ( SC-941, optional ).

Calibrator

B & K (Bruel & kjaer), Multifunction Acoustic Calibrator 4226.

Datalogger Sampling Time Setting range

Auto

1 second to 3600 seconds
@ Sampling time can set to 1 second, but memory data may loss.


Manual

Push the data logger button once will save data one time.
@ Set the sampling time to 0 second.
@ Manual mode, can also select the 1 to 99 position ( Location ) no.

Memory Card

SD memory card. 1 GB to 16 GB.

Advanced setting

Set clock time ( Year/Month/Date, Hour/Minute/ Second )
Decimal point of SD card setting
Auto power OFF management
Set beep Sound ON/OFF
Set sampling time
SD memory card Format

Over Indication

Show " - - - - ".

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Sampling Time of Display

Approx. 1 second.

Data Output

RS 232/USB PC computer interface.
Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
Connect the optional USB cable USB-01 will get the USB plug.

Power off

Auto shut off saves battery life or manual off by push button.

Operating Temperature

0 to 50oC.

Operating Humidity

Less than 85% R.H.

Power Supply

AC/DC power adapter is optional. Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.

DC 9V adapter input. ( AC/DC power is optional. adapter is optional ).

Power Current

Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 8.5 mA.

When SD card save the data but and LCD Backlight is OFF) : Approx. DC 30 mA.

If LCD backlight on, the power consumption will increase approx. 14 mA.

Weight

489 g/1.08 LB.

Dimension

245 x 68 x 45 mm. ( 9.6 x 2.7x 1.9 inch ).

Accessories Included

Instruction manual..............................1 PC
Hard carrying case, CA-06............... 1 PC

Optional Accessories

Sound calibrator ( 94 dB ), SC-941.
Sound calibrator ( 94/114 dB ), SC-942.
Sound wind shield ball, SB-01
SD Card ( 2 GB )
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software, SW-U801-WIN.
AC to DC 9V adapter.
Soft carrying case, CA-05A.


ENGINEERING AND ENVIRONMENTAL SOLUTIONS

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.